Safety Access Control Controller
  • Safety Access Control Controller
  • EF-SNK8000 Access controller 1
  • EF-SNK8000 Access controller 1

Safety Access Control Controller

Model No.: EF-SNK8000

  • User capacity: 156,000 cards
  • Number of records: 300,000 stored records
  • Communication method: RS485/TCP/IP
  • Card reader input format: Wiegand26 \ Wiegand34 \ Wiegand66

Safety Access Control Controller

Introduction:

EF-SNK8000 access control controller adopts network design thinking, adopts super 32-bit core processor and massive FLASH memory development and design, realizes communication networks such as local area network and wide area network, and supports super high-speed data storage. The built-in operation stability monitoring module ensures the safe and stable operation of the access control controller products. If there is an abnormality, it will automatically record and notify the management system, making the operation of each system more clear and stable. The controller has built-in fire alarm input and output and bandit alarm input and output. In addition, it can be externally connected to an alarm expansion board to support fire alarms, bandit police, anti-theft, poisonous gas and other alarms. Using multi-network architecture design, the product supports multi-computer management access and voice output, which can effectively guide users to understand current events in a specific state.

Product Description:

EF-SNK8000 access control controller adopts network design thinking, adopts super 32-bit core processor and massive FLASH memory development and design, realizes communication networks such as local area network and wide area network, and supports super high-speed data storage. The built-in operation stability monitoring module ensures the safe and stable operation of the access control controller products. If there is an abnormality, it will automatically record and notify the management system, making the operation of each system more clear and stable. The controller has built-in fire alarm input and output and bandit alarm input and output. In addition, it can be externally connected to an alarm expansion board to support fire alarms, bandit police, anti-theft, poisonous gas and other alarms. Using multi-network architecture design, the product supports multi-computer management access and voice output, which can effectively guide users to understand current events in a specific state.

System Functions:

Standard function support: offline operation, card reading to open the door, password to open the door, period control password valid, card reading + password to open the door, period control card reading + password to be effective, manual input of card number + password to open the door, first card to open the door, normally open card to open the door, Remote door opening, remote door closing, timed door opening, time period normally open, real-time monitoring, abnormal monitoring, electronic map, coercion alarm, fire linkage, bandit police alarm, intrusion alarm, illegal card reading alarm, loss card reporting, blacklist card reading alarm, Door opening timeout prompt/alarm, anti-pass back and anti-tailing, batch upload, small amount upload, double door interlock, multi door interlock, multi card door opening, keyboard operation, emergency door closing, access control attendance, 64 groups of door opening time periods, holidays, etc.

Professional function support: card return, record restoration, anti-detection lock, card reading verification, full card opening, full card opening + automatic registration, motherboard buzzer switch, clock self-repair, internal and external authentication, and 3+1 authentication , Inquiry of the number of people in the door, telephone connection notification after the alarm, the number of days the equipment has been running, remote hardware program upgrade, etc.

New features support: Card reader line abnormality detection and prompt, static QR code to open the door, dynamic QR code to open the door, ID number to open the door, voice prompt guidance, system ambient temperature detection, input power temperature monitoring, trial period, access control online patrol Update, advance reminder of card expiration date, intelligent clock error self-correction every day, exit switch controlled by time period, remote card reading and photography, anti-theft alarm host function, card reading interval setting, door magnetic alarm time period management, communication encrypted data, card New functions such as valid times, self-expansion of capacity, and WIEGAND keyboard card issuance. Simultaneous link management of 5 computers, regional multi-board prevention, regional multi-board interlocking, built-in BS management system, long-distance active connection back to the server, multi-card opening of group A+B, and advance reminder of the validity period of elastic cards.

Support site access control function: support pedestrian gate management, can realize two-way control, provide LED screen information output, LCD TV screen information output, support site information display, and support unified management of card reading, fingerprints, and faces (one set of software for unified management ) to support multi-platform data upload.

Product Parameters:

  • User capacity: 156,000 cards
  • Number of records: 300,000 stored records
  • Communication method: RS485/TCP/IP
  • Card reader input format: Wiegand26 Wiegand34 Wiegand66
  • Support type: EM/IC/CPU/second-generation ID card/second-generation residence permit/fingerprint/bluetooth card/microwave card/face
  • Number of management doors: 1 (single door) / 2 (double doors) / 4 (four doors)
  • Number of card readers that can be connected: 2 (single door) / 4 (double door) / 8 (four door)
  • Exit switch: 1 group (single door) 2 groups (double door) 4 groups (four doors)
  • Door magnetic interface: 1 group (single door) 2 groups (double door) 4 groups (four doors)
  • Alarm expansion: 4 in 4 out (fire, bandit police, anti-theft, poison gas)
  • Communication distance: TCP/IP (100 meters)
  • Wiegand: 100 meters (80 meters recommended)
  • Size: single door double door 157*130*20mm four door 212*130*20mm
  • Working voltage: DC9V-14V
  • Working current: <300mA

System Software:

EF-SNK8000 series controller adopts C2 one-card management system as system software, which is suitable for one-card management system as system software. The system software supports two databases of SQL and ACCESS, and supports WINXP, WIN2003, WIN7, WIN10 and other system platforms.

The one-card management system adopts nine modular structure design: system data module, system graphic monitoring module, personnel management module, access control system module, attendance system module, elevator access control module, patrol system module, meeting check-in module, consumption management Modules are equal to one.

Multilingual format: Simplified Chinese version English version

Provide a secondary development package for the system to centrally connect to the software platform

ELEFINE Access controller Connection diagram

Wiring Requirements for Access Controllers:

  • 1. AC220V AC power cord: It is recommended to use 3*1.0 square millimeter (or more) wire to prevent leakage and grounding of the ground wire of the power cord;
  • 2. Electric locking wire: 2*1.0 square millimeter (or more) wire must be used, and the maximum length of the line should not exceed 50 meters;
  • 3. TCP/IP communication cable: please use standard network cable, and the maximum length of the line should not exceed 100 meters;
  • 4. Card reader line: It is recommended to use 8*0.5 square millimeter (or more) wire, and the longest line should not exceed 80 meters;
  • 5. Door sensor or exit switch wire: It is recommended to use 2*0.5 square millimeter (or more) wire, and the line length should not exceed 100 meters.

Safety Access Control Controller Wiring Diagram:

Safety Access Control Controller Wiring Diagram: