Factory 10 Million Cycles DC Brushless Motor Automatic Parking Boom Gate Barrier
Specifications:
Model No.: EF-BB818
Working voltage: 24V+10%/50HZ
Motor power: 140W
Chassis color: black, yellow, gold
Ambient temperature: -30℃~80℃
Relative humidity: ≤95%
Length of the barrier rod: can be customized according to the actual situation on site
Lift time: generally 1.5~6S
Height of the center of the brake lever from the ground: 850mm
Remote control distance: ≤40m
Protection class: IP44
Input interface: +12V level signal or pulse signal greater than 100ms; drive current: less than 10mA
Chassis size: 355mm×280mm×1000mm
Carton size: 420*390*1080mm
Chassis weight: 50KG
Installation Notes:
Open the packing box and check the relevant random spare parts according to the spare parts list.
Determine the installation position of the main gate of the gate according to the left and right direction of the selected gate and the actual situation of the installation site. For non-concrete foundations or when the main body of the road gate is installed with a slope, it is recommended to build a concrete foundation, and it should be ensured that the foundation and the foundation are firmly combined, and the verticality of the main body of the main body of the road gate to the horizontal plane is less than 1°.
According to the location of the control room or guard box, lay the power line and control line pipe according to the relevant regulations in “GB232 Electrical Installation Engineering Construction and Acceptance Specification” (it is recommended that the power line and control line be put in different line pipes).
Install expansion screws (determined according to the accessories actually equipped in the list) at the installation position of the main gate of the gate, and fix the main machine of the gate firmly before use.
Use the crank handle to shake the brake lever to the horizontal position, determine the installation position of the fork lever at the end of the brake lever, and fix the fork lever firmly with screws (no need to install if there is no fork lever).
Carefully check the wiring diagram, connect the power cord and related control lines to the gate control board, and then tighten and debug after confirming that they are correct.
Note: The above operations should be performed under the condition of power off.
Specific Operation of Boom Barrier Gate:
(1) Line pre-buried
The position of the chassis is determined according to the customer’s requirements. If the concrete base needs to be poured, it can be completed in advance (the size of the base is about 100-150mm larger than the outer dimension of the bottom of the gate). Pre-embed or excavate cable trenches between guard boxes, bury line pipes, and penetrate 3X1.5 square millimeters of power lines and 4X0.5 square millimeters of control lines used for equipment. After confirmation, backfill concrete.
(2) Fixed chassis
Put the chassis in a fixed position, open the chassis door, then mark the center of the screw holes on the chassis bottom plate and the edge of the chassis base, remove the gate, and drill vertically with a drill bit on the marked screw holes (the size of the drill bit should be the same as that of the chassis). Match the expansion bolts with the equipment), and the depth should meet the length requirements of the expansion bolts. Move the chassis to its original position, drive in the expansion screws and fasten them firmly.
(3) Installation of brake lever
After the gate case is firmly fixed, the gate rod can be installed at the position of the rod handle, tightened with the provided screws, and ensure that the gate rod is not inclined. If you need to install the fork rod, after debugging the vertical and horizontal states, use the crank handle to shake the brake rod to the horizontal position, determine the installation position of the fork rod at the end of the brake rod, and fix the fork rod firmly with screws (No need to install if there is no fork lever).
(4) Installation of peripheral equipment
The gate is installed firmly, and after the debugging is completed, according to the needs of the customer, the chassis circuit and the control circuit of the related peripheral equipment can be connected according to the wiring diagram of the gate control board, and related debugging can be carried out.