Security and protection:
power off data protection
with offline testing function
safety protection conditions can be set, setting parameters include: voltage upper limit, voltage lower limit, current upper limit, current lower limit, capacity upper limit, delay time, protection grade IP20
Cyclic test range: 1~65535 times
Single cycle number of steps: 254
Nested loop: With nested loop function, maximum support for three levels of nesting
DCIR test: Support custom pick point for DCIR calculation
The pulse mode
charging: Constant current mode, constant power mode
discharge: Constant current mode, constant power mode
Minimum pulse width: 500ms
The number of pulses: Single pulse workstep supports 32 different pulses
Charging and discharging switch continuously: A pulse working step can realize the continuous switch from charging to discharging
As conditions: Voltage, relative time
Charging
Charging mode: Constant current charging, constant voltage charging, constant current constant voltage charging, constant power charging
As conditions:Voltage, current, relative time, capacity,V
Discharge
Discharge patterns: Constant current discharge, constant power discharge and constant resistance discharge
As conditions: Voltage, current, relative time, capacity, V
Voltage
constant voltage range control: 25mV~5V
minimum discharge voltage: The two ends of the upper and lower fixture can discharge to 1.0v, and the 2m line length can be up to 1.5v
Accuracy: ± 0.05% of FS
Stability: ± 0.05% of FS
Electricity
precision: ± 0.05% of FS
Constant voltage cut-off current: 12mA
Stability: ± 0.05% of FS
Power
Single channel output power: 30W
stability: ± 0.1% of FS
Data records
Data recording condition:
Minimum sampling time: 100ms
Minimum sampling voltage: 10mV
Minimum sampling current: 6mA
Record the frequency: 10 hz