Model No. EF-CT-4008T-5V6A-S1/164
EF-CT-4008T-5V6A is one of the best selling models which is widely used in cell manufacturers, universities and labs worldwide. It’s great for testing different sizes of cylindrical, pouch and coin cells. Elefine has launched new EF-CT-4008T-5V6A with three output current ranges which can improve the testing accuracy based on varying charging/discharging current. Each EF-CT-4008T-5V6A has 8 channels, and each channel is independent. Working with Elefine powerful software, it can be your best partner in the daily test.
CV output range: 25mV~5V
Min discharge voltage: 1V for universal holder,2M line length up to 1.5V
Accuracy: ± 0.05% FS
Stability: ± 0.05% FS
Output range/channel: Range1: 0.5mA-0.1A; Range2: 0.1A-3A; Range3: 3A-6A
Accuracy: ± 0.05% FS
CV cut-off current: Range1: 0.2mA; Range2: 6mA; Range3: 12mA
Stability: ± 0.05% FS
Output power/channel 30 W
Stability ± 0.1% of FS
Current response time <1ms (10%FS~90%FS)
Working step time ≤(365*24)h/step Time format-00:00:00.000 (h, m, s, ms)
Data record conditions:
Min data record interval: 100ms
Min voltage change: 10mV
Min current change: Range1: 0.2mA; Range2: 6mA; Range3: 12mA
Frequency: 10Hz
Charge modes: CC, CV, CCCV, CP
Cut-off condition Voltage, Current, Time, Capacity, Energy, -△V
Discharge modes: CC, CV, CCCV, CP, CR
Cut-off condition: Voltage, Current, Time, Capacity, Energy
Charge: CC, CP
Discharge: CC, CP
Min pulse width: 500ms
Pulse counts: Up to 32
Chg and Dschg switch: Supported
Cut-off condition: Voltage, Time
Max cycles: 65535
Max steps: 254
Cycle nest: 3
Safety protection:
Power-failure data protection
Offline operation mode
User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc.
To meet the various requirements adopted in advanced battery research, our equipments can automatically switch the current range in accordance with user settings to maintain consistent accuracy, and can be fitted with additional hardware to provide a number of optional features and capabilities. The model EF-CT-4008T-5V6A can be configured with multi-current range channels, which have a current control range of 0.5mA to 0.1A, 0.1A to 3A, 3A to 6A as standard. The accuracy for current and voltage on these channels is ±0.05% FS.
5V6A uses one fan, but 5V12A uses two.
The inventive heat-radiating system is practical and feasible and can increase heat-radiating efficiency and space utilizaion rate. Each EF-CT-4008T-5V6A supports from one to eight test channels, depend on the application.Each test channel is operated independently. This allows different tests to be performed on different test channels simultaneously, with tests being started independently, or in a block.
Compared with 5V6A, 5V12A uses two square fans for dissipating heat. Industrial design is delicate.
EF-CT-4008T-5V6A battery testing system combined one middle machine, which can work with up to 10 sets of 5V6A equipments. What’s more, you can use one gantry to DIY a new equipment. The most surprising thing is that it can save much more floor space.
ELEFINE battery charge and discharge test system realizes integrated operation and collaborative work through BTS upper computer control system, so as to maximize the battery characteristics and functions.
Good news for lithium battery manufacturers
Using polymer clamps to test, such as 6545 polymer clamp.
The upper and lower clamps of Neware 5V6A and 5V12A tester can move up and down accurately according to the scale marked on the left and right sides. The cylinder battery is tested between the upper and lower clamps.
Using polymer clamps to test, such as 6545 polymer clamp.
A large number of 5V6A testing equipments are running at customer’ sites.